How to Store and Recall Voltage and Current setups with 9110 power supply
2019-12-23
The below instructions provide a few step by step guidance to storing and saving voltage and current values into internal memory for 9110 power supply. To store settings, do the following:
- Set the group to be used for storing settings. The instrument can store up to 100 groups. Each group can store up to 4 settings, which include voltage and current settings. To verify or change group, press shift and hold down “D V/A” button for 3 seconds until the voltage display shows “OVP”.
- Press “C” button until display shows “GrP” at the top. Below this shows a number. This is the “group number”. Use the rotary knob to change the number. Press “C” after any changes to save changes and exit the setup menu.
- Enter the voltage and current settings you want to store. Use the “D V/A” key to toggle between setting voltage and current.
- Now, press “shift” and “A” button. There will be 4 green dots blinking on the display, next to the “A” “B” “C” “D” labels.
- Now, press “A” again if you want to store to “A”. “B” for “B”. “C” or “C”. Or “D” for “D”. Once you click any of the 4 buttons, the display will return to the main display.
- Repeat steps 2-4 if you want to store multiple settings within the same group.
To recall the stored settings, do the following:
- Press “shift” and “B” button to go into Preset mode. On the display, there should be a green dot next to the Preset label to indicate preset mode.
- Now, press either “A”, “B”, “C”, or “D” button to recall the stored settings accordingly.
- The restored voltage and current settings will display temporarily for 3 seconds and will go back to 0 if output is off. If output is already on, display will show measured values based on the set voltage and current values.